Forged Male Run Tee

Forged Male Run Tee

Typical application scenarios Installation of pressure gauge/sensor: A threaded interface is branched out on the main pipeline (compression connection) for installing a pressure gauge or sensor. Connecting valves: A threaded interface is branched out on the main pipeline for installing ball...
Send Inquiry
Product Introduction
Part# Comp*
Male NPTF
(1*3)*2
A B Body
Size
PARKER EATON MAF GATES DIXOH Tectran Fairview Tramec
Sloan
1119-2C 1/8*1/8 0.63 0.69 0.36 171C-2-2   18272   171C-0202     S71-2-2
1119-3C 3/16*1/8 0.63 0.69 0.36 171C-3-2 71x3 18273 G55130-0203 171C-0302 71-3A 71-3A S71-3-2
1119-4C 1/4*1/8 0.68 0.72 0.36 171C-4-2 71x4 18274 G55130-0204 171C-0402 71-4A 71-4A S71-4-2
1119-4D 1/4*1/4 0.68 0.80 0.37 171C-4-4   18275 G55130-0404 171C-0404   71-4B S71-4-4
1119-5D 5/16*1/8 0.73 0.73 0.44     18276 G55130-0205       S71-5-2
1119-5C 5/16*1/4 0.75 0.88 0.44     18277         S71-5-4
1119-6D 3/8*1/8 0.75 0.75 0.50     18278       716A S71-6-2
1119-6C 3/8*1/4 0.77 0.94 0.49 171C-6-4 71x6 18279 G55130-0406 171C-0604 71-6B 71-6B S71-6-4
1119-6E 3/8*3/8 0.77 0.98 0.49     18281       71-6C S71-6-6
1119-8E 1/2*3/8 0.94 1.09 0.59     18282 G55130-0608   71-8C   S71-8-6
1119-8F 1/2*1/2 0.94 1.19 0.55     18283       72-8D S71-8-8
1119-10F 5/8*1/2 1.06 1.31 0.69     18284          
1119-12F 3/4*1/2 1.22 1.34 0.88     18284          

 

 

 

Typical application scenarios

 

 

Installation of pressure gauge/sensor: A threaded interface is branched out on the main pipeline (compression connection) for installing a pressure gauge or sensor.
Connecting valves: A threaded interface is branched out on the main pipeline for installing ball valves, angle valves, etc. to control branch flow.
Equipment interface: Connect the main pipeline to equipment with internal thread interfaces (such as boilers, pumps, filters, coolers, etc.).
Conversion connection method: In the compression connection piping system, a component originally designed for threaded connection needs to be connected.
Instrument air pipeline: Provide a branch with a threaded interface for pneumatic tools or equipment on the compressed air main pipeline.
Hydraulic/lubricating oil circuit: Provide a branch on the main pipeline for lubrication points or hydraulic components that require threaded connections (pay attention to fluid compatibility).
Refrigeration system: Used to connect components with threaded interfaces such as pressure switches and sight glasses.

 

 

 

Products Description

 

 

Key considerations and installation points
Port identification, be sure to distinguish which is the compression end and which is the external thread end.
Thread standard confirmation, the external thread standard of the branch end must be clear (BSPP, BSPT, NPT, NPTF, etc.), and ensure that the internal thread port standard connected to it is completely matched. Mixing threads of different standards will result in loose connections, leakage, or even damage to the threads.
Sealing method selection:
Parallel threads must use suitable flat washers. The size and material must match (usually provided with the connector or purchased separately). When tightening, the end face seal can be formed by reaching the specified torque.
Tapered threads (BSPT/R, NPT/NPTF): Thread sealants (such as PTFE raw tape or anaerobic thread glue) must be used. The raw tape must be wound in the correct direction (in the direction of the thread) and the number of turns is moderate (usually 2-4 turns). When tightening, the appropriate tightness must be achieved. Over-tightening may cause cracking.
Compression end installation: Strictly follow the standard compression joint installation specifications:
The pipe is cut flat and burred.
The pipe is fully inserted into the body.
Use two wrenches (one to hold the body and one to tighten the nut).
Tighten to the number of turns specified by the manufacturer. Do not overtighten.
Pipe compatibility: Compression ends are only suitable for specified rigid pipe OD (such as copper pipe, certain stainless steel pipe). Make sure the pipe material and OD match the fitting specifications.
Pressure and temperature: Confirm that the rated working pressure and temperature range of the fitting meet the system requirements.
Fluid compatibility: Make sure the brass material is suitable for the fluid being transported. Only use products that are clearly certified for use in gas systems.
Avoid stress: After installation, make sure that the piping system does not impose excessive bending or torsional stress on the tee fitting.